一、練化尾氣發(fā)電機組工作接地 

1、 Grounding of the exhaust gas generator set during operation

(1)降低觸電電壓。對于中性點不接地的系統(tǒng),當(dāng)一相接地而人體觸及另外兩相之一時,觸電電壓為相電壓的1.7倍以上;而對于中性點接地系統(tǒng),觸電電壓就降到接近或等于相電壓。

(1) Reduce the electric shock voltage. For systems where the neutral point is not grounded, when one phase is grounded and the human body touches one of the other two phases, the electric shock voltage is more than 1.7 times the phase voltage; For neutral grounding systems, the electric shock voltage drops to near or equal to the phase voltage.

(2)迅速切斷故障設(shè)備。對于中性點不接地的系統(tǒng),當(dāng)一相接地時,由于導(dǎo)線和地面存在電容和絕緣電阻,可以構(gòu)成電流通路,接地電流很小,不足以使保護裝置動作而切斷電源,不能確保人身安全。而對于中性點接地的系統(tǒng),當(dāng)一相接地后接地電流較大,保護裝置會迅速動作,斷開故障點。

(2) Quickly cut off the faulty equipment. For systems with a neutral point that is not grounded, when one phase is grounded, due to the capacitance and insulation resistance between the wire and the ground, a current path can be formed. The grounding current is very small and not enough to activate the protective device and cut off the power supply, which cannot ensure personal safety. For systems with neutral grounding, when the grounding current is large after one phase is grounded, the protection device will quickly operate to disconnect the fault point.

(3)降低電氣設(shè)備對地的絕緣水平。在中性點不接地的系統(tǒng)中,當(dāng)一相接地時,將會使另兩相得對地電壓升高到線電壓。而對于中性點接地的系統(tǒng),當(dāng)一相接地時,另兩相的對地電壓只接近于相電壓,故可降低電氣設(shè)備和輸電線路的絕緣水平。

(3) Reduce the insulation level of electrical equipment to the ground. In a neutral ungrounded system, when one phase is grounded, it will cause the ground voltage of the other two phases to rise to the line voltage. For systems with neutral grounding, when one phase is grounded, the ground voltage of the other two phases is only close to the phase voltage, which can reduce the insulation level of electrical equipment and transmission lines.

044417f42c04859cffcd34857cb3f18

 二、煉化尾氣發(fā)電機組保護接地 保護接地常用于中性點不接地的低壓系統(tǒng)中,它的作用是:當(dāng)電動機某一繞組的絕緣結(jié)構(gòu)已破壞使外殼帶電時,如果未接地,人體觸及外殼,相當(dāng)于單相觸電,就可能發(fā)生觸電的危險。而如果采用了保護接地,人體觸及外殼時,由于人體的電阻與接地電阻并聯(lián),由于人體電阻;遠大于接地電阻,通過人體的電流就很小,就不會發(fā)生觸電的危險。

2、 The protective grounding of the refining tail gas generator set is commonly used in low-voltage systems where the neutral point is not grounded. Its function is that when the insulation structure of one winding of the motor has been damaged, causing the shell to be charged, if it is not grounded and the human body touches the shell, it is equivalent to single-phase electric shock, which may pose a risk of electric shock. If protective grounding is used, when the human body touches the shell, the resistance of the human body is connected in parallel with the grounding resistance; Far greater than the grounding resistance, the current passing through the human body is very small, so there is no risk of electric shock.

三、煉化尾氣發(fā)電機組保護接零 保護接零常用于中性點接地的低壓系統(tǒng)中,它的作用是:當(dāng)電動機某一繞組的絕緣結(jié)構(gòu)已破壞而與外殼相接時,由于采用保護接零,就形成單相短路,迅速將這一相中的熔絲熔斷,外殼便不再帶電。即使在熔絲熔斷前人體觸及外殼時,也由于人體電阻遠大于線路電阻,通過人體的電流也很微小,不會發(fā)生觸電危險。 另外還需注意,發(fā)電機零線接地要考慮具體的情況,先要確認(rèn)變壓器是否有漏電保護單獨接地,零線和市電的零線接在一起。相線(三相線)要用開關(guān)把市電和發(fā)電做互鎖控制,以免市電加在發(fā)電機組上。

3、 The protective zero connection of the refining tail gas generator set is commonly used in low-voltage systems with neutral grounding. Its function is that when the insulation structure of a certain winding of the motor is damaged and connected to the casing, a single-phase short circuit is formed due to the use of protective zero connection. The fuse in this phase is quickly melted, and the casing is no longer charged. Even when the human body touches the outer shell before the fuse is blown, the current passing through the human body is very small due to the much higher resistance of the human body compared to the line resistance, and there is no risk of electric shock. In addition, it should be noted that the grounding of the generator's neutral wire should consider the specific situation. First, it is necessary to confirm whether the transformer has a separate grounding for leakage protection, and whether the neutral wire and the neutral wire of the mains power are connected together. The phase line (three-phase line) should be interlocked with a switch to control the mains and power generation, in order to prevent the mains from being added to the generator set.

本文由煉化尾氣發(fā)電機組友情奉獻.更多有關(guān)的知識請點擊:http://m.maryke8.com我們將會對您提出的疑問進行詳細的解答,歡迎您登錄網(wǎng)站留言.

This article is a friendly contribution from the Refining and Chemical Exhaust Gas Generator Unit For more information, please click: We will provide detailed answers to your questions. You are welcome to log in to our website and leave a message

相關(guān)產(chǎn)品 / Related products

聯(lián)系我們
    濟南濟柴環(huán)能燃氣發(fā)電設(shè)備有限公司
  • 國內(nèi)業(yè)務(wù):羅總18653152416
    王總13012995645
  • 國外業(yè)務(wù):李總18668968402
    張總18678860619
  • 座 機:0531-62325028 / 69951266
  • 傳 真:0531-69958299
  • 郵 箱:hengnenghr@163.com
  • 地 址:中國(山東)自由貿(mào)易試驗區(qū)濟南片區(qū)孫村街道經(jīng)十東路33688號章錦綜合保稅區(qū)聯(lián)東U谷科創(chuàng)中心5號樓101
濟南濟柴環(huán)能燃氣發(fā)電設(shè)備有限公司     網(wǎng)站備案號:魯ICP備18052890號-3  網(wǎng)站地圖 XML TXT

截屏,微信識別二維碼

微信號:王總13012995645

點擊微信號復(fù)制,添加好友

 打開微信