燃氣發(fā)電機組質(zhì)量良好,性能穩(wěn)定。發(fā)電機組工作時只有旋轉(zhuǎn)運動,電調(diào)反應(yīng)速度快,工作平穩(wěn),發(fā)電機輸出電壓和頻率的精度高,波動小,在突加空減50%和75%負載時,機組運行穩(wěn)定。燃氣發(fā)電機組優(yōu)點多,但是對燃氣管道有要求!
The gas generator unit has good quality and stable performance. When the generator unit works, it only rotates. The electric regulation has fast response speed and stable operation. The generator output voltage and frequency have high accuracy and small fluctuation. When the load is suddenly increased by 50% and 75%, the unit operates stably. There are many advantages of gas generator sets, but there are requirements for gas pipelines!
燃氣發(fā)電機組燃氣管道應(yīng)采用鋼管,管壁不應(yīng)太薄,接頭處要密封可靠,燃氣管線連接完成后,用燃氣檢測儀或肥皂水檢測管線滲漏情況,法蘭閥門等接頭處。
The gas pipeline of the gas generator unit shall be made of steel pipe, the pipe wall shall not be too thin, and the joints shall be sealed reliably. After the gas pipeline is connected, the leakage of the pipeline, flange valve and other joints shall be detected with gas detector or soapy water.
應(yīng)定期檢查閥門,應(yīng)無燃氣泄漏損壞等現(xiàn)象,閥門周圍應(yīng)無妨礙閥門操作的堆積物,閥門應(yīng)定期進行啟閉操作和維護保養(yǎng),無法啟閉或關(guān)閉不嚴的閥門,應(yīng)及時維修或更換。
The valve shall be checked regularly to ensure that there is no gas leakage or damage. There shall be no accumulation around the valve that hinders the operation of the valve. The valve shall be opened and closed regularly and maintained. The valve that cannot be opened or closed tightly shall be repaired or replaced in time.
燃氣發(fā)電機組燃氣管線上的膠管應(yīng)定期更換,嚴禁使用過期老化膠管。

The rubber hose on the gas pipeline of the gas generator unit shall be replaced regularly. It is strictly prohibited to use the expired rubber hose.
對機組及燃氣管線進行運行維護和搶修時,須可靠地切斷燃氣來源并將內(nèi)部燃氣排凈,未查明事故原因和采取措施前,不得向燃氣設(shè)施恢復送氣。進行維護檢修時,應(yīng)采取防爆措施或使用防爆工具,嚴禁用鐵器等工具進行敲擊作業(yè)。
During the operation, maintenance and emergency repair of the unit and gas pipeline, the gas source must be reliably cut off and the internal gas must be discharged. Before the cause of the accident is found out and measures are taken, the gas supply to the gas facilities cannot be restored. Explosion-proof measures or tools shall be taken during maintenance and overhaul. It is strictly forbidden to use tools such as iron tools to knock.
燃氣泄漏的搶修應(yīng)在切斷氣源后進行,當泄漏處已發(fā)生燃燒時,應(yīng)先采取措施控制火勢后再切斷氣源,嚴禁管道內(nèi)出現(xiàn)負壓。
The emergency repair of gas leakage shall be carried out after cutting off the gas source. When the leakage has been burned, measures shall be taken to control the fire before cutting off the gas source. Negative pressure in the pipeline is strictly prohibited.
本文由加燃氣發(fā)電機組配件整理發(fā)布,您是不是對這些內(nèi)容有所了解了呢?更多的內(nèi)容請點擊:
http://m.maryke8.com我們會有更多精彩內(nèi)容等你查看。
This article is organized and released by the accessories of gas-fired generator set. Do you know something about these contents? For more information, please click:
http://m.maryke8.com We will have more wonderful content waiting for you to check.